Coil Heaters

As a complementary equipment Margo offers electric coil heaters made of stainless steel including customised thermostat.

Fast heat exchange between water and the heater is possible due to its construction; no magnesium anode is required. Heater’s cover is made of plastic and includes temperature adjustment and a temperature limiter. The equipment can be assembled to heat exchangers, tanks or mixers. There are one and three phase types of heaters.

Temperature ranges:

– from 30°C to 85°C

– from 30°C to 140°C

One-phase heaters

One-phase heating bars are suitable for direct water heating. They consist of a single coil heater U shaped and a temperature control cover mounted in a head with a thread 6/4”, optionally 5/4”.

Technical data

Heater diameter: 8,5mm

Made of material: 1.4404 / 1.4876 / 2.4858

Head including thread: 5/4″, 6/4″, 2″

Head made of stainless steel AISI 304

Power range: 2,0 – 12,0 kW

Plastic ABS cover 100x100x110mm in black

Cable connector M20x1,5

Security level IP54

Temperature control: one-phase 30-85°C, STB 110°

coil heaters

Table of a typical heating bars

Thread G 5/4”

Thread G 6/4”

Power [W]

Voltage [V]

Length L [mm]

Ampacity w/cm2

WP 12.360.20

WP 15.360.20

2000

230

360

8-10

WP 12.360.30

WP 15.360.30

3000

230

360

 

Three-phase heaters with temperature control.

Three-phase heating bars are suitable for direct water heating alike one-phase ones. They consist of 3 coil heaters U shaped and a temperature control cover mounted in a head.

Heater diameter: 8,5mm

Made of material: 1.4404 / 1.4876 / 2.4858

Head including thread: 6/4″, 2″

Head made of stainless steel AISI 304

Power range: 3,0 – 12,0 kW

Plastic ABS cover 100x100x110mm in black

Cable connector M20x1,5

Security level IP54

Temperature control: three-phase, 30-75°C, STB 98°C (30-85°C, STB 110°C option)

coil heaters

Table of typical heating bars

Thread G 6/4”

Thread G2”

Power [kW]

Voltage [V]

Length L [mm]

Ampacity W/cm2

WP 15.250.20

2,5

230/400

300

5-6

WP 15.350.30

3,0

230/400

350

WP 15.450.40

4,5

230/400

450

WP 15.650.60

WP 20.650.60

6,0

230/400

650

WP 15.800.75

WP 20.800.75

7,5

230/400

800

WP 15.200.20

2,5

400

200

8-10

WP 15.250.30

3,0

400

250

WP 15.350.45

4,5

400

350

WP 15.450.60

WP.20.450.60

6,0

400

450

WP 15.650.90

WP.20.650.90

9,0

3×400

650

WP 15.800.120

WP.20.800.120

12,0

3×400

800

 

Choice of the heater according to temperature and capacity of the heat exchanger, tank or mixer.

 

Capacity of: heat exchanger, tank, mixer

 

100L

150L

200L

250L

300L

350L

400L

450L

500L

550L

600L

 

Heater power (kW) installed for increasing the temperature by 10°C

30 min

3,3

4,4

5,6

7,0

8,1

9,3

10,7

12.1

13,3

14,7

15,9

60 min

1,6

2,2

2,8

3,5

4,1

4,6

5,4

6,1

6,7

7,4

7,9

1h 30 min

1,1

1,5

1,8

2,3

2,7

3,5

4,0

4,6

5,0

5,5

5,9